GPD 503 SIMPLIFIED START-UP PROCEDURE
This procedure will quickly get you up and running by Digital Operator keypad or user suppliedremote operator control. lt assumes that the GPD 503 and motor are correctly wired (see pages1-8 thru 1-15), and start-up is to be performed without any changes to factory set constants.)etailed information on the many other features of this drive will be found in later sections of thismanual.
INSTALLATION
1.Be certain your input voltage source, motor, and drive name plates are all marked either 230V460V, or 575V. Other voltages can be used, but require additional programming, see Section
2. Mount drive on a vertical surface with adequate space for air circulationRemove front cover, fit conduit to bottom plate, and connect power and ground wires asshown.
CAUTION
Be certain you connect input power to terminals L1, L2, and L3 only, or serious damagewill result. Connect motor to terminals T1 T2, and T3 only.
KEYPAD OPERATION
Replace cover and apply input power - keypad display shows " F00.00 "; DRIVE, FWD, andSTOP lamps are on. Press and hold JOG key, noting direction of motor rotation. If it isincorrect, remove power, wait for “CHARGE" light to go out, then switch wires betweenterminals T1, and T2. Replace cover, and apply input power.
Run, Stop, and Frequency (Speed) - Here, the terms frequency and speed are usedinterchangeably. A value of 60.00 (Hz) in the “F00.00 " display equals full speed (frequency)for common motors. Press RUN key; RUN lamp lights, STOP lamp flashes (to indicate drive isrunning at zero speed) Note flashing "0" in “F00.00 " display. Press "up arrow" key one timeto increase display frequency value to 10.00. Press DATA/ENTER key to enter speed data,noting that motor shaft begins to turn. Repeat this procedure using "up arrow", “down arrow'and "right arrow"(RESET) keys to introduce various speeds, noting that the drive responds toeach new value only after the DATA/ENTER key is pressed. The “ F00.00 " display indicatesthe frequency command the drive is looking at, whether it is running or not.
Reversing - can be selected while stopped, or while running. With the drive stopped, pressFWD/REV key and note the REV lamp lights and FWD lamp goes out. lf drive is runningwhen this key is pressed, the drive will decelerate the motor to 0 Hz, then accelerafe themotor to the same speed in the opposite direction. You can try this while running, providedyour machine can be operated in reverse direction without damage.
Displays - With drive stopped, each time the DISPL (display) key is pressed, a differentfunction appears. The first function on power up is the “F00.00 " display, discussed above.Press DISPL and “0.00 appears; this is a display of output frequency (speed) and isrecognized as the only display without alpha characters. The next is “0.0A "; the “A" indicatesthis display is output amps. For other display information, refer to Section 3.
The following is my contact information, you are very welcome to come to me for inquiries:
Contact person:Panda
Email Address::panda@fenoux.com
WhatApp: +86 13376987741
RELATED PRODUCTS
ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
AGILENT G2630-66015 |
Hefei Banyitong Science & Technology Developing Co., Ltd, established in 1994, we are professional manufacturer in material handling equipments and special logistic equipment, our brand "MIMA" have 12 series and 50 models according to long-time technology